10 Configuring GigE Vision Devices
10-14
Timeout for heartbeat – the camera requires that the application send a packet every
so often (like a heartbeat) to keep the control connection alive. This is the setting for that
packet period. Setting it too low can add unnecessary load to the computer and to the
camera. Setting it too high can cause the camera to remain in use too long beyond when
the toolbox attempts to relinquish control, leading to a failure to obtain control to start
another acquisition.
Retries for commands – this is the number of attempts that the toolbox will make
to send a command to the camera before deciding that the send has failed. The time
between retries is set by the Timeout for packet acknowledgement setting.
Disable camera IP correction – check if you want to disable automatic IP correction
for your camera. Clear the check mark to re-enable IP correction.