Seitenansicht 320
Dyadic Synthesis Filter Bank
5-164
asymmetric tree structure generates 2
n
-2 zero-valued output samples in each
channel before propagating the first synthesized output sample (computed
from the inputs received at t=0).
See “Excess Algorithmic Delay (Tasking Latency)” in Chapter 3 and “The
Simulation Parameters Dialog Box” in the Simulink documentation for more
information about block rates and Simulink’s tasking modes.
Dialog Box
Lowpass FIR filter coefficients
A vector of filter coefficients (descending powers of z) to be shared by all the
lowpass filters in the filter bank.
Highpass FIR filter coefficients
A vector of filter coefficients (descending powers of z) to be shared by all the
highpass filters in the filter bank.
Number of levels
The number of filter bank levels. An n-level asymmetric structure has n+1
inputs; an n-level symmetric structure has 2
n
inputs.
Tree structure
The structure of the filter bank,
Asymmetric (wavelet) or Symmetric.
References Fliege, N. J. Multirate Digital Signal Processing: Multirate Systems, Filter
Banks, Wavelets. West Sussex, England: John Wiley & Sons, 1994.