Filter Requirements with User Tags
4-29
8
Reopen the Requirements Settings dialog box to the Filters tab.
9
In the Include links with any of these tags field, delete test. In the Exclude
links with any of these tags field, add test.
In the model, the highlighting changes to exclude objects whose requirements have
the test user tag. The MAP sensor and Test inputs blocks are no longer highlighted.
10
In the Simulink Editor, select Analysis > Requirements Traceability >
Generate Report.
The report does not include information about objects whose requirements have the
test user tag.
Apply User Tags During Selection-Based Linking
When creating a succession of requirements links, you can apply the same user tags to all
links automatically. This capability, also known as selection-based linking, is available
only when you are creating links to selected objects in the requirements documents.
When creating selection-based links, specify one or more user tags to apply to
requirements:
1
In the Simulink Editor, select Analysis > Requirements Traceability > Settings.
2
Select the Selection Linking tab.