2 Building Simple Models with SimEvents Software
2-38
Add the Network Delay Subsystem Contents
In this procedure, you add event-based blocks that model a communications delay to the
Network Delay subsystem block. When you complete the procedure, the contents of the
Network Delay block should look as shown in the graphic.
1
In the SimEvents library, double-click the Generators library. Double-click the
Entity Generators sublibrary and drag a Time-Based Entity Generator block into
the subsystem window.
2
To review the entity generation behavior of the Time-Based Entity Generator block,
double-click it. The default value of Generate entities upon is Intergeneration
time from dialog, with a default intergeneration period of 1 s. Accept these
default values without making any change by clicking Cancel.
3
In the Generators library, double-click the he Signal Generators sublibrary.
Drag the Event-Based Random Number block into the subsystem window.
4
Double-click the Event-Based Random Number block. Set Distribution to Uniform,
Minimum to 0.01, and Maximum to 0.06. Click OK. These settings ensure that
the service time of the N-Server block varies with a uniform distribution of values
between a minimum of 0.01s and a maximum of 0.06s.
5
From the Attributes library, drag the Set Attribute and Get Attribute blocks into
the subsystem window.
6
Double-click the Set Attribute block. The Set Attribute tab of the dialog box
contains a table. On the first row of the table, set Name to Value and set Value
From to Signal port. Click OK. The block acquires an extra signal input port,
Value.